Vertical Transportation

 

Vertical transportation is provided to the Building through thirty-two passenger elevators and three service elevators.

Listed below is pertinent information about the Building’s vertical transportation system.

Bank “A”: Passenger Elevators (PE-16, PE-17, PE-18, PE-19 and PE-20)

  1. Capacity: 4,000 lbs.
  2. Floors Served: G, M, 2 through 7 (Note: PE-18 also services the concourse and sub-basement levels)
  3. Rated Speed: 600 fpm
  4. Clear Door Opening: 48” W x 84” H
  5. Net Inside Cab Area: 89” W x 66” D
  6. Floor to Ceiling Measurement: 89” to dome

 Bank “B”: Passenger Elevators (PE-5, PE-6 and PE-7)

  1. Capacity: 4,000 lbs.
  2. Floors Served: G, M, 2 through 4
  3. Rated Speed: 500 fpm
  4. Clear Door Opening: 48” W x 84” H
  5. Net Inside Cab Area: 89” W x 66” D
  6. Floor to Ceiling Measurement: 89” to dome

Bank “C”: Passenger Elevators (PE-21, PE-22, PE-23, PE-24, PE-25, PE-26, PE-27 and PE-28)

  1. Capacity: 4,000 lbs.
  2. Floors Served: G, 11 through 23
  3. Rated Speed: 1,000 fpm
  4. Clear Door Opening: 48” W x 84” H
  5. Net Inside Cab Area: 89” W x 66” D
  6. Floor to Ceiling Measurement: 89” to dome

 Bank “D”: Passenger Elevators (PE-29, PE-30, PE-31, PE-32, PE-33, PE-34, PE-35 and PE-36)

  1. Capacity: 4,000 lbs.
  2. Floors Served: G, 24 through 42
  3. Rated Speed: 1,200 fpm
  4. Clear Door Opening: 48” W x 84” H
  5. Net Inside Cab Area: 89” W x 66” D
  6. Floor to Ceiling Measurement: 89” to dome

 Bank “E”: Passenger Elevators (PE-8, PE-9, and PE-10)

  1. Capacity: 3,500 lbs.
  2. Floors Served: G, 2 through 4
  3. Rated Speed: 500 fpm
  4. Clear Door Opening: 48” W x 84” H
  5. Net Inside Cab Area: 89” W x 66” D
  6. Floor to Ceiling Measurement: 89” to dome

 Bank “F”: Passenger Elevators (PE-11, PE-12, PE-13, PE-14, and PE-15)

  1. Capacity: 3,500 lbs.
  2. Floors Served: G, 5 through 10
  3. Rated Speed: 600 fpm
  4. Clear Door Opening: 48” W x 84” H
  5. Net Inside Cab Area: 89” W x 66” D
  6. Floor to Ceiling Measurement: 89” to dome

 Bank “S”: Service Elevators (SE-2, SE-3)

  1. Capacity: 3,500 lbs.
  2. Floors Served:
    • SE-2: SC through 28
    • SE-3: SC through 43
  3. Rated Speed: 800 fpm
  4. Clear Door Opening: 52” W x 84” H
  5. Net Inside Cab Area: 81” W x 68” D
  6. Floor to Ceiling Measurement: 90” to dome

Bank “S”: Service Elevator (SE-4)

  1. Capacity: 7,000 lbs.
  2. Floors Served: SC through 43
  3. Rated Speed: 500 fpm
  4. Clear Door Opening (SC, G): 90” W x 120” H
  5. Clear Door Opening (C, 2 through 43): 90” W x 84” H
  6. Net Inside Cab Area: 90” W x 80” D
  7. Floor to Ceiling Measurement: 128” to dome

Passenger and service elevators are regularly inspected and professionally maintained by a specialized maintenance firm.  Should the elevator stop while you are in it, be assured that you are safe.  Use the emergency button to summon help, and then communicate via the emergency intercom.

Elevator equipment and performance are constantly monitored.  Should you at any time experience any irregularity or difficulty with elevator service, please note the elevator car number and report it immediately to the Main Lobby Desk or the Property Management Office.

If normal electrical service to the building is interrupted, the elevator lights at the front of the elevator car panel will blink and the elevators will temporarily stop.  Sensing the lack of normal power, the base building generator will start and each car will return to the main lobby level one car at a time where the doors will open allowing you to exit.

The closed circuit television cameras installed in each elevator are monitored by Building Security personnel and are recorded at all times.  In addition to being monitored, the elevator system is equipped with lock-out features that enable the Building personnel to secure each elevator car on a floor-by-floor basis after hours.